Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38183467

RESUMO

PURPOSE: The purpose of this study is to assess the diagnostic accuracy of ChatGPT in the field of ophthalmology. METHODS: This is a retrospective cohort study conducted in one academic tertiary medical center. We reviewed data of patients admitted to the ophthalmology department from 06/2022 to 01/2023. We then created two clinical cases for each patient. The first case is according to the medical history alone (Hx). The second case includes an addition of the clinical examination (Hx and Ex). For each case, we asked for the three most likely diagnoses from ChatGPT, residents, and attendings. Then, we compared the accuracy rates (at least one correct diagnosis) of all groups. Additionally, we evaluated the total duration for completing the assignment between the groups. RESULTS: ChatGPT, residents, and attendings evaluated 126 cases from 63 patients (history only or history and exam findings for each patient). ChatGPT achieved a significantly lower accurate diagnosis rate (54%) in the Hx, as compared to the residents (75%; p < 0.01) and attendings (71%; p < 0.01). After adding the clinical examination findings, the diagnosis rate of ChatGPT was 68%, whereas for the residents and the attendings, it increased to 94% (p < 0.01) and 86% (p < 0.01), respectively. ChatGPT was 4 to 5 times faster than the attendings and residents. CONCLUSIONS AND RELEVANCE: ChatGPT showed low diagnostic rates in ophthalmology cases compared to residents and attendings based on patient history alone or with additional clinical examination findings. However, ChatGPT completed the task faster than the physicians.

2.
Can J Ophthalmol ; 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38219792

RESUMO

OBJECTIVE: It is accepted that ocular parameters are more correlated with the fellow eye. This poses a challenge in ophthalmic research. There is a relative scarcity of data concerning the extent of correlation. The aim of this study was to analyze and quantify the correlation of different ocular parameters. DESIGN: Historical registry analysis. PARTICIPANTS: All patients examined in a 10-year period (2011-2021) in one academic tertiary medical centre in central Israel. METHODS: Data from optical coherence tomography examinations and biometry of a single examination of both eyes taken at the same time from each patient was included. Pearson's r values were calculated to estimate the extent of correlation. RESULTS: A total of 17,212 patients were included. Mean age was 73 ± 12.7 years, and 54.5% were female. All examined parameters were highly statistically significantly correlated between eyes (all with p < 0.1 × 10-36), whereas the strength of correlation differed. Very weak correlation was seen in central macular thickness (r = 0.189), and a weak correlation was seen in anterior-chamber depth (r = 0.379) and retinal nerve fibre layer thickness (r = 0.479). A strong correlation was seen in central corneal thickness (r = 0.754), and a very strong correlation was seen in axial length (r = 0.900). CONCLUSIONS: In a retrospective analysis of optical coherence tomography and biometry measurements of >10,000 patients, all examined parameters were highly statistically significantly correlated. Correlation magnitude varied, with structural characteristics more correlated than functional ones. Including both eyes in an outcome analysis likely will introduce bias. We recommend adjusting for inter-eye correlation in all studies assessing ocular outcome measures.

3.
Eur J Ophthalmol ; 34(1): 119-125, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37128126

RESUMO

PURPOSE: To investigate the influence of post-operative eye patching on corneal thickness, endothelial cells' loss and visual acuity in patients diagnosed Fuchs' endothelial corneal dystrophy (FECD). SETTING: Public healthcare centre, Shamir Medical Centre, Israel. METHODS: This randomized controlled trial included patients with FECD undergoing routine cataract surgery in a public medical centre. Patients were randomly assigned to 2 groups: the eye undergoing surgery was covered with a patch for 24 h in the first group (patched group), and a plastic shield was used in the second (non-patched group). Both groups received a unique dose of a local steroid and antibiotic post-operatively. The eyes were examined pre-operatively, and on days 1, 7 and 30 post-surgery . Examination included: best corrected visual acuity (BCVA), comeplete slit lamp examination, intra ocular pressure (IOP), anterior chamber depth (ACD), central corneal thickness (CCT) using the IOL Master 700 (Zeiss, Germany) and endothelial cell density (ECD) using Specular microscopy. Cumulative dissipated energy (CDE) and operation time were recorded for all cases. RESULTS: The study included 46 eyes of 46 patients diagnosed with FECD. Twenty-three eyes in the patched group, and 23 eyes in the non-patched group . Thirty days post-operatively the CCT in the patched group decreased by 60 ± 38 mµ (9%) compared to 92 ± 80 mµ (13.5%) in the non- patched group (p = 0.04). Seven days post-operatively the CCT in the patched group decreased by 31 ± 35 mµ (5%) compared to 58 ± 76 (8%) in the non-patched group, but this difference did not reach statistical significance (p = 0.081). There was no statistically significant difference in endothelial cells loss as well as BCVA at 1, 7 and 30 days post-operatively between the study groups. CONCLUSIONS: Avoiding eye patch post-operatively after cataract surgery in patients with FECD results in better corneal clarity recovery and reduced corneal edema one month post-operatively. Visual acuity and endothelial cell's loss were not influenced by patching.


Assuntos
Catarata , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs , Humanos , Células Endoteliais , Distrofia Endotelial de Fuchs/cirurgia , Distrofia Endotelial de Fuchs/diagnóstico , Córnea , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Implante de Lente Intraocular , Endotélio Corneano
4.
Retina ; 44(1): 78-82, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37607406

RESUMO

PURPOSE: To evaluate the risk of a retinal redetachment in women after vaginal delivery versus cesarean delivery. METHODS: Retrospective cohort analysis of patients diagnosed with retinal detachment (RD) who had later delivered in one tertiary medical center. Recurrence rates of RD were obtained from medical charts. RESULTS: A total of 967 women with RDs were evaluated, and 66 patients met the inclusion criteria. The mean age at the time of RD was 22.64 ± 5.81 SD years and 21.75 ± 5.47 SD years in the vaginal delivery group and the cesarean section group, respectively. None of the patients had a history of eye surgery or traumatic eye injury before the event of RD. In all patients, the detached retina was surgically reattached. Retinal detachment was not recorded in the fellow eye during follow-up. We report four cases of redetachment after birth in four women. In our study, there was a 5% rate (n = 2) of RD after a vaginal delivery as compared with a 7.5% (n = 2) redetachment rate for patients after a cesarean delivery ( P = 0.654). CONCLUSION: The risk of a redetachment of the retina in women is not increased after a vaginal delivery as compared with a cesarean delivery. Therefore, in our opinion, there is no ophthalmic benefit in a cesarean section for a woman with prior RD.


Assuntos
Cesárea , Descolamento Retiniano , Humanos , Feminino , Gravidez , Cesárea/efeitos adversos , Estudos Retrospectivos , Descolamento Retiniano/diagnóstico , Descolamento Retiniano/epidemiologia , Descolamento Retiniano/etiologia , Parto Obstétrico/efeitos adversos , Estudos de Coortes
6.
J Neuroophthalmol ; 43(1): 29-33, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36790061

RESUMO

BACKGROUND: To describe recent cases of optic neuritis in patients who received a vaccine for COVID-19. METHODS: Retrospective case series of patients diagnosed with optic neuritis after a recent COVID-19 vaccination with BNT162b2 (Pfizer-BioNTech), in one university-affiliated tertiary hospital, from January 2021 to June 2021. Data were obtained from medical charts. RESULTS: We describe 7 patients who developed optic neuritis after immunization with the BNT162b2 vaccine. CONCLUSIONS: A causal relationship cannot be deduced, and the importance of COVID-19 vaccination is not challenged. However, the authors encourage a prospective monitoring and reporting system for all patients receiving COVID-19 vaccines, to further assess the spectrum of adverse events in large databases.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Neurite Óptica , Humanos , Vacina BNT162 , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Neurite Óptica/diagnóstico , Neurite Óptica/etiologia , Estudos Prospectivos , Estudos Retrospectivos , SARS-CoV-2 , Vacinação/efeitos adversos
7.
Eye (Lond) ; 37(9): 1834-1839, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36127423

RESUMO

OBJECTIVE: To evaluate the accuracy of the ABCD Progression Display and the ABCD grading system in a population of adult patients with keratoconus. METHODS: A retrospective cohort analysis of all adult patients with keratoconus followed at the Shamir Medical Center between 2012 and 2017. A recommendation by the cornea specialist to undergo corneal crosslinking (CXL) was used as a surrogate of ectasia progression. The ABCD grading was not available to the treating physician and was computed post-hoc. Sensitivity and specificity of the ABCD Progression Display was calculated, and multivariate regression was used to estimate the risk to undergo CXL when the ABCD Progression Display indicated progression. The ABCD grading was compared between patients who required CXL to those who did not. A single eye of each patient was included. Sensitivity and specificity of the ABCD Progression Display were 82% and 73%, respectively. A multivariable model adjusted for possible confounders, found that ABCD Progression was associated with a 7-fold risk of undergoing CXL compared to a patient in whom progression was not recorded in the ABCD Progression Display (OR = 7.55; 95% CI = 3.82-14.93, p < 0.001). RESULTS: 293 eyes of 293 patients were analysed. Mean age at presentation was 26.92 ± 6.12 years. In 68 eyes, progression of keratoconus was recorded and CXL was performed (CXL-group). CONCLUSION: The ABCD Progression Display demonstrated adequate sensitivity and specificity and high predictive capabilities of keratoconus progression. It can be effectively utilized as an initial screening test in adults with keratoconus.


Assuntos
Ceratocone , Fotoquimioterapia , Adulto , Humanos , Adulto Jovem , Ceratocone/diagnóstico , Ceratocone/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Riboflavina/uso terapêutico , Colágeno/uso terapêutico , Reagentes de Ligações Cruzadas/uso terapêutico , Raios Ultravioleta , Topografia da Córnea
8.
Eye (Lond) ; 37(6): 1219-1224, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35590103

RESUMO

PURPOSE: Standard corneal collagen cross-linking (S-CXL) is an effective treatment to arrest Keratoconus (KC) progression in children. Less is known on the long-term efficacy of accelerated CXL (A-CXL) in paediatric populations. METHODS: A historical cohort analysis of paediatric patients (≤18 years) with KC who underwent S-CXL and A-CXL at two tertiary referral centres in Israel between 2010-2017. Preoperative and 3-year postoperative evaluation included changes in visual acuity (best spectacle corrected [BSCVA]) and uncorrected [UCVA]), refractive errors, and keratometric data. RESULTS: Ninety-three eyes of 93 patients were analysed (A-CXL: n = 39; S-CXL: n = 54). Baseline characteristics were similar between groups. Both groups showed a significant improvement in visual acuity compared to baseline (S-CXL: 0.810-0.602 LogMAR UCVA; A-CXL: 0.890-0.306 LogMAR UCVA, p < 0.05 for both). Improvement in BSCVA and UCVA following A-CXL was non-inferior to S-CXL (< ± 0.2 LogMAR). Kmax decreased by a mean of 0.98 ± 5.56 dioptres following S-CXL (p = 0.02) and by 1.48 ± 8.4 dioptres following A-CXL (p = 0.015). Thinnest pachymetry decreased following both treatments (S-CXL: by 26.8 ± 40.7 µm, p = 0.001, A-CXL: by 10.2 ± 13.4 µm, p = 0.028), the difference between groups was within the non-inferiority margin (< ± 10 µm). CONCLUSIONS: Paediatric patients followed for three years after A-CXL showed improved visual function, reduced corneal astigmatism and Kmax, and decreased thinnest corneal thickness. A-CXL was non-inferior to S-CXL at three years in terms of best-corrected and uncorrected visual acuity, thinnest pachymetry, and astigmatism. For Kmax, non-inferiority could not be concluded.


Assuntos
Ceratocone , Fotoquimioterapia , Humanos , Criança , Ceratocone/tratamento farmacológico , Crosslinking Corneano , Fármacos Fotossensibilizantes/uso terapêutico , Seguimentos , Raios Ultravioleta , Riboflavina/uso terapêutico , Topografia da Córnea , Reagentes de Ligações Cruzadas/uso terapêutico
9.
Cornea ; 2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38166187

RESUMO

PURPOSE: The aim of the study was to evaluate the efficacy and safety of quantum molecular resonance in the treatment of dry eye disease. METHODS: This study was a double-blind randomized control trial in 1 academic medical center, for 2 years. Participants received treatment or a placebo with the Rexon-Eye device, once per week for 4 weeks. The primary outcome was the change in dry eye symptoms assessed by the Ocular Surface Disease Index (OSDI). Secondary outcomes were clinical findings associated with the dry eye such as meibomian gland dysfunction (MGD) score, tear break-up time (TBUT), corneal fluorescein staining, Schirmer test, and best-corrected visual acuity (BCVA). RESULTS: Forty patients were recruited, 20 in each arm. The mean age was 63.5 ± 15.1 years and 27 (67.5%) were female. The mean OSDI score significantly improved in the intervention group from 19.15 ± 10.3 to 10.5 ± 7.0 (P < 0.001), whereas the control group showed no significant change (14.4 ± 8.4 to 15.5 ± 8.6, P = 0.830). MGD scores significantly improved in the intervention group (1.57 ± 1.2 to 0.8 ± 0.9, P = 0.006), whereas showing no significant change in the control group (1.60 ± 0.9 to 1.99 ± 1.0, P = 0.244). The corneal staining score also showed significant improvement in the intervention group (P = 0.045) and a nonsignificant decline in the placebo group (P = 0.50). No significant difference was seen in TBUT, visual acuity, and Schirmer scores between groups. No harm resulting from treatment was reported during the duration of the trial. CONCLUSIONS: High-frequency electrotherapy may have a positive effect on symptoms and signs of dry eye. This emerging technology may become part of the arsenal of therapeutic modalities for this condition.

10.
J Refract Surg ; 38(10): 668-673, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36214349

RESUMO

PURPOSE: To assess the refractive prediction error of four intraocular lens (IOL) calculation formulas in eyes that have undergone scleral fixation using the four-flanged technique. METHODS: This was a retrospective cohort analysis of patients who underwent scleral fixation using the four-flanged technique at the Shamir Medical Center between 2020 and 2021. Refractive prediction errors for four IOL prediction formulas (Barrett Universal II, Holladay 1, SRK/T, and Kane) were obtained by subtracting the predicted spherical equivalent from the postoperative spherical equivalent. Mean arithmetic refractive prediction error and mean absolute error were calculated and compared. RESULTS: Twenty-three eyes of 23 patients were included in the analysis. The Akreos AO60 IOL (Bausch & Lomb, Inc) was implanted in 9 eyes and the BunnyLens HP IOL (Hanita Lenses) in 14 eyes. Mean age was 72.84 ± 13.2 years. All formulas produced myopic mean arithmetic refractive prediction error. Mean arithmetic refractive error and mean absolute error were equal in absolute number. Mean arithmetic refractive prediction errors were -0.72 diopters (D) for Barrett Universal II, -0.61 D for Holladay 1, -0.77 D for SRK/T, and -0.94 D for Kane formulas. The refractive outcome differed significantly from the predicted refraction in all formulas. There were no statistically significant differences in prediction errors between the formulas. CONCLUSIONS: Refractive outcomes of the four-flanged fixation technique produced myopic results compared to the predicted refraction for all formulas tested. This suggests that the effective lens position is more anterior than in-the-bag IOL implantation. [J Refract Surg. 2022;36(10):668-673.].


Assuntos
Lentes Intraoculares , Miopia , Facoemulsificação , Erros de Refração , Idoso , Idoso de 80 Anos ou mais , Biometria/métodos , Humanos , Implante de Lente Intraocular/métodos , Pessoa de Meia-Idade , Miopia/cirurgia , Óptica e Fotônica , Refração Ocular , Estudos Retrospectivos
11.
Eur J Ophthalmol ; 32(3): 1482-1490, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34058903

RESUMO

BACKGROUND: Retrospective cohort study evaluating long term keratoconus progression amongst cross-linking (CXL) treated pediatric patients in the treated and the fellow untreated eyes. METHODS: Data on 60 eyes of 30 patients, 18 years old or younger, who underwent CXL in at least one eye was collected and analyzed. Follow-up measurements taken from the treated and untreated eye up to 7 years after CXL treatment, were compared to baseline measurements. Parameters included uncorrected distance visual acuity (UCDVA), best-corrected spectacle visual acuity (BCSVA), manifest refraction, pachymetry, corneal tomography, and topography. RESULTS: Mean age of patients was 16 ± 2.1 years. For the treated eyes, during follow-up period mean UCDVA had improved (from 0.78 ± 0.22 at baseline to 0.58 ± 0.26 logMAR at 7 years; p = 0.13), as well as mean BCSVA (from 0.23 ± 0.107 at baseline to 0.172 ± 0.05 logMAR at 7 years; p = 0.37). The mean average keratometry showed a significant flattening (from 49.95 ± 4.04 to 47.94 ± 3.3 diopters (D); p < 0.001), However there was no change in the mean maximal keratometry. The mean minimal corneal thickness (MCT) showed a significant mild reduction of 26 µm (p = 0.006). Although statistically insignificant, the mean manifest cylinder was also reduced to 2D (p = 0.15). During the follow-up period, eight untreated eyes (26.6%) deteriorated and underwent CXL, while only one treated eye (3.33%) required an additional CXL. CONCLUSION: CXL is a safe and efficient procedure in halting keratoconus progression in the pediatric population, the fellow eye needs to be carefully monitored but only a 25% of the patients will require CXL in that eye during a period of 7 years.


Assuntos
Ceratocone , Fotoquimioterapia , Adolescente , Criança , Colágeno/uso terapêutico , Topografia da Córnea , Reagentes de Ligações Cruzadas/uso terapêutico , Seguimentos , Humanos , Ceratocone/diagnóstico , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Riboflavina/uso terapêutico , Raios Ultravioleta
12.
Can J Ophthalmol ; 57(3): 147-153, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34052223

RESUMO

OBJECTIVE: To characterize the association between prolonged supine postoperative positioning of patients undergoing Descemet-stripping automated endothelial keratoplasty (DSAEK) and graft dislocation rate. METHODS: In this retrospective cohort study, medical records of patients who underwent uncomplicated DSAEK surgery at Yitzhak Shamir Medical Center between 2010 and 2019 were reviewed. Nursing documentation of patients' adherence to supine positioning during the postoperative hospitalization period was collected. A patient was considered compliant if he or she was documented as cooperative with supine positioning throughout the first 24 hours. RESULTS: A total of 170 eyes of 138 patients were found eligible. Main indications for surgery were pseudophakic bullous keratopathy (50.6%), previous graft failure (25.9%), and Fuch's endothelial dystrophy (FED; 20.6%). Twelve surgeries were combined with cataract extraction. Postoperative graft detachment occurred in 26 eyes (15.3%) after an average period of 1 day (range, 0-20 days). Compliance with supine positioning was documented in 84.1% (n = 143 patients). Noncompliance rates during the first 24 hours in the detached and nondetached groups were 26.9% (n = 7) and 14.4% (n = 20), respectively; after adjustment for possible confounders, the odds ratio (OR) was 1.44 (p = 0.249). Graft dislocation was observed in 13.3% (19 of 143) and 25.9% (7 of 27) of cooperative and noncooperative patients, respectively (p = 0.17). Subanalysis of 120 eyes with either BPK or FED for which it was the first transplantation demonstrated a protective effect of supine positioning (OR 3.42, confidence interval 1.095-10.700; p = 0.034). Findings for both groups remained unchanged in multivariate analysis. CONCLUSIONS: We found a statistically significant protective effect of 24 hours of postoperative supine positioning against graft detachment after DSAEK in eyes with no prior transplantations.


Assuntos
Doenças da Córnea , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs , Doenças da Córnea/cirurgia , Endotélio Corneano , Feminino , Distrofia Endotelial de Fuchs/cirurgia , Sobrevivência de Enxerto , Humanos , Estudos Retrospectivos , Decúbito Dorsal , Acuidade Visual
13.
Eye (Lond) ; 36(6): 1261-1265, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34140653

RESUMO

OBJECTIVES: To compare the visual outcome of patients treated for non-arthritic central retinal artery occlusion (CRAO) in a medical centre that uses hyperbaric oxygen therapy (HBOT) as part of the standard of care (SOC) to medical centres that does not. METHODS: The study included data from two tertiary medical centres. The medical records of all patients diagnosed with non-arthritic CRAO without a patent cilioretinal artery between January 2010 and December 2018 in two tertiary medical centres were reviewed. RESULTS: One hundred and twenty-one patients were treated by HBOT and 23 patients received only SOC. In the HBOT group, best-corrected visual acuity (BCVA) improved from 2.89 ± 0.98 logMAR at presentation to 2.15 ± 1.07 logMAR upon the end of HBOT (P < 0.001), while the SOC group had no significant improvement, from 3.04 ± 0.82 logMAR at presentation to 2.80 ± 1.50 logMAR (P = 0.24). With adjustment for age, gender, and the duration of symptoms, final BCVA in the HBOT group was significantly better compared to the control group (P = 0.023). Rates of patients achieving vision of 20/200 or better were similar between groups (17.4% vs. 19.8%, P = 0.523). CONCLUSION: Utilizing HBOT as part of the SOC for CRAO improves the final visual outcome. HBOT is safe and can be implemented, if available, as part of SOC in all tertiary medical centres.


Assuntos
Oxigenoterapia Hiperbárica , Oclusão da Artéria Retiniana , Artérias Ciliares , Humanos , Oxigênio , Oclusão da Artéria Retiniana/terapia , Estudos Retrospectivos
14.
Eye (Lond) ; 36(9): 1772-1776, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34373609

RESUMO

OBJECTIVE: To evaluate the incidence of consecutive exotropia following bilateral medial rectus muscle recession surgery (BMR) for esotropia using non-absorbable compared with absorbable sutures in children undergoing strabismus surgery. METHODS: A retrospective cohort study of all children with esotropia who underwent BMR by a single surgeon in a tertiary public hospital. As of February 2018, only non-absorbable sutures were used. The primary outcome was the incidence of consecutive exotropia. RESULTS: A total of 121 children were included in the analysis, 3.66 ± 2.62 years, 53% were male. In 80 children (66%) non-absorbable sutures were used (non-absorbable group) and in 41 children (34%) absorbable sutures were used (absorbable group). Consecutive exotropia (≥ 8 prism dioptres) occurred in ten children (24%) in the absorbable group and in three children (4%) in the non-absorbable group (OR = 8.28, 95% CI = 2.13-32.13; P = 0.002). This difference between groups remained significant after adjustment for potential confounders and follow-up time (HR = 4.98, 95% CI = 1.30-19.05, P = 0.019). Mean follow-up time was 22 and 12 months in the absorbable and non-absorbable groups, respectively (P < 0.001). Two children in the non-absorbable group had pyogenic granuloma that resolved after 3 months of topical steroidal therapy. CONCLUSION: Routine use of non-absorbable sutures in BMR surgery for esotropia may be a preferable alternative to absorbable sutures for the prevention of consecutive exotropia.


Assuntos
Esotropia , Exotropia , Criança , Esotropia/cirurgia , Exotropia/cirurgia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Músculos Oculomotores/cirurgia , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos , Estudos Retrospectivos , Suturas/efeitos adversos , Resultado do Tratamento , Visão Binocular/fisiologia
15.
J Cataract Refract Surg ; 47(9): 1227-1233, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34468460

RESUMO

A modification of intraocular lens (IOL) implantation, using the 4-flanged IOL fixation technique, through a 2.4 mm corneal incision using a standard cartridge and injector, is presented. An IOL with 4 eyelets is used, through which a 6-0 polypropylene suture is threaded on one side and then loaded into a provided cartridge and inserted to the anterior chamber through a 2.4 mm corneal incision. Using the handshake technique, the suture ends are eventually threaded through the eyelets and secured outside the eye with the creation of 4 flanges. This technique was used in 6 eyes of 5 consecutive patients with the absence of capsular support. During all follow-up visits, the IOLs were well centered and stable, and the flanges were buried in the sclera and covered with the conjunctiva. No complications were recorded. This modification simplifies the technique and reduces the well-known complications of large corneal incisions.


Assuntos
Lentes Intraoculares , Humanos , Implante de Lente Intraocular , Esclera/cirurgia , Técnicas de Sutura , Acuidade Visual
16.
Cornea ; 40(10): 1322-1329, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34481408

RESUMO

PURPOSE: To evaluate the ABCD grading system in pediatric keratoconus. METHODS: A retrospective cohort analysis of all children with keratoconus followed up at the Shamir medical center between 2010 and 2017. A recommendation by the treating physician to undergo corneal crosslinking (CXL) was used as an estimate for clinically significant disease progression. The ABCD grading was not available to the treating physician and was computed post hoc. The ABCD grading was compared between patients who required CXL with those who did not. A single eye of each patient was included. RESULTS: Fifty eyes of 50 children were analyzed. The mean age at presentation was 15.56 ± 1.36 years. In 23 eyes, progression of keratoconus was recorded and CXL was performed (CXL-group). On presentation, the stable and CXL groups did not differ significantly in their clinical parameters. In the CXL-group, a statistically significant increase was seen in the ABCD staging (P < 0.001). In the stable group, the ABCD staging did not change significantly in parallel visits (P = 0.87). An increase of 1 point in the sum of the ABCD staging showed a 5-fold risk for undergoing CXL (odds ratio = 5.28; 95% CI, 1.82-15.34). There was no significant change in the Amsler-Krumeich classification in the CXL group. CONCLUSIONS: Among a cohort of pediatric patients with keratoconus, worsening in the ABCD grading was associated with disease progression, whereas no significant change was demonstrated in the Amsler-Krumeich classification The ABCD grading system is a useful tool for initial assessment of disease progression in the pediatric population, in which early recognition is of paramount importance.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Ceratocone/classificação , Ceratocone/diagnóstico , Adolescente , Colágeno/metabolismo , Paquimetria Corneana , Substância Própria/efeitos dos fármacos , Substância Própria/metabolismo , Reagentes de Ligações Cruzadas/uso terapêutico , Progressão da Doença , Feminino , Humanos , Ceratocone/tratamento farmacológico , Masculino , Fotoquimioterapia , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Raios Ultravioleta , Acuidade Visual/fisiologia
17.
JAMA Otolaryngol Head Neck Surg ; 147(8): 739-743, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34165512

RESUMO

Importance: Peripheral facial nerve (Bell) palsy has been reported and widely suggested as a possible adverse effect of the BNT162b2 (Pfizer-BioNTech) COVID-19 vaccine. Israel is currently the leading country in vaccination rates per capita, exclusively using the BNT162b2 vaccine, and all residents of Israel are obligatory members of a national digital health registry system. These factors enable early analysis of adverse events. Objective: To examine whether the BNT162b2 vaccine is associated with an increased risk of acute-onset peripheral facial nerve palsy. Design, Setting, and Participants: This case-control study was performed from January 1 to February 28, 2021, at the emergency department of a tertiary referral center in central Israel. Patients admitted for facial nerve palsy were matched by age, sex, and date of admission with control patients admitted for other reasons. Exposures: Recent vaccination with the BNT162b2 vaccine. Main Outcomes and Measures: Adjusted odds ratio for recent exposure to the BNT162b2 vaccine among patients with acute-onset peripheral facial nerve palsy. The proportion of patients with Bell palsy exposed to the BNT162b2 vaccine was compared between groups, and raw and adjusted odds ratios for exposure to the vaccine were calculated. A secondary comparison with the overall number of patients with facial nerve palsy in preceding years was performed. Results: Thirty-seven patients were admitted for facial nerve palsy during the study period, 22 (59.5%) of whom were male, and their mean (SD) age was 50.9 (20.2) years. Among recently vaccinated patients (21 [56.7%]), the mean (SD) time from vaccination to occurrence of palsy was 9.3 (4.2 [range, 3-14]) days from the first dose and 14.0 (12.6 [range, 1-23]) days from the second dose. Among 74 matched controls (2:1 ratio) with identical age, sex, and admittance date, a similar proportion were vaccinated recently (44 [59.5%]). The adjusted odds ratio for exposure was 0.84 (95% CI, 0.37-1.90; P = .67). Furthermore, analysis of the number of admissions for facial nerve palsy during the same period in preceding years (2015-2020) revealed a relatively stable trend (mean [SD], 26.8 [5.8]; median, 27.5 [range, 17-35]). Conclusions and Relevance: In this case-control analysis, no association was found between recent vaccination with the BNT162b2 vaccine and risk of facial nerve palsy.


Assuntos
Paralisia de Bell/etiologia , Vacinas contra COVID-19 , Vacinas contra COVID-19/efeitos adversos , Estudos de Casos e Controles , Feminino , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Centros de Atenção Terciária
18.
Eur J Ophthalmol ; 31(6): 3332-3336, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33685221

RESUMO

PURPOSE: To report the outcomes of superior oblique split tendon elongation in Brown's syndrome. METHODS: Charts of 17 consecutive Brown's syndrome patients who underwent superior oblique split tendon elongation were reviewed and clinical data regarding preoperative, intraoperative, and postoperative data were collected. RESULTS: About 17 eyes of 17 children with congenital Brown's syndrome underwent superior oblique split tendon elongation between January 2012 and March 2020 by a single surgeon. Mean age at surgery was 5.47 ± 2.82 (range 1.50-13.2). Eight (47.1%) were female. Preoperative deficit of elevation in adduction was -4 in all children. At the end of surgery, all eyes were freely elevated on adduction, on forced duction test. Mean follow-up time of 26.24 ± 11.22 (range 11-53) months. In 15 of 17 children (88.2%), motility improved, orthotropia in primary position was achieved, and head posture eliminated (p < 0.001). Superior oblique palsy occurred in two children, who after reoperation, achieved an acceptable outcome. No intraoperative complications were recorded. CONCLUSION: The superior oblique split tendon elongation procedure is a useful surgical technique with stable and satisfying outcomes for the treatment of severe congenital Brown's syndrome.


Assuntos
Transtornos da Motilidade Ocular , Tendões , Criança , Olho , Feminino , Humanos , Transtornos da Motilidade Ocular/cirurgia , Músculos Oculomotores/cirurgia , Reoperação , Tendões/cirurgia
19.
Int Ophthalmol ; 41(2): 433-440, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32929665

RESUMO

PURPOSE: Coronavirus disease 2019 (COVID-19) caused a global pandemic with millions infected worldwide. Little is known on the ocular involvement associated with the disease. The aim of this study was to assess the clinical and molecular ocular involvement among patients with confirmed COVID-19 admitted to a tertiary care facility. METHODS: Consecutive patients admitted to the COVID-19 Ward of the Shamir Medical Center in Israel during March and April, 2020 were included. The control group included patients negative for COVID-19 admitted during a similar period to a different ward. Patients were examined by trained Ophthalmologists. SARS-CoV-2 conjunctival swab samples were obtained. RESULTS: Included were 48 patients, 16 with confirmed COVID-19 and 32 controls. Median patient age was 68.5 (interquartile range: 31.5, mean: 63 ± 21) years and 48% were male. Active conjunctival injection was present in three patients (19%) with COVID-19, compared to none in the controls (p = 0.034). Patients with COVID-19 were more likely to complain of foreign body sensation (31.3% vs 3.1%, p = 0.005) and redness of the eye (25% vs 0%, p = 0.003). Conjunctival injection was associated with loss of smell and taste (75% vs 7.7%, p = 0.018). Viral conjunctival swab tests all showed negative results for all three viral genes tested (E, N, and RdRp). CONCLUSIONS: Among patients admitted to a tertiary referral center with confirmed COVID-19, active conjunctival injection was noted in one out of five cases, and was associated with loss of smell and taste. Conjunctival swabs for viral RNA were negative in patients with and without ocular involvement.


Assuntos
COVID-19/epidemiologia , Infecções Oculares Virais/epidemiologia , Pandemias , RNA Viral/análise , SARS-CoV-2/genética , Idoso , Infecções Oculares Virais/diagnóstico , Infecções Oculares Virais/virologia , Feminino , Humanos , Incidência , Israel/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Aesthet Surg J ; 41(6): NP464-NP471, 2021 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-32427315

RESUMO

BACKGROUND: Late-onset upper eyelid edema is an uncommonly recognized complication of hyaluronic acid (HA)-based filler injection to the supraorbital area. OBJECTIVES: The authors sought to report their experience in diagnosing and managing late-onset upper eyelid edema. METHODS: This was a noncomparative, retrospective study of a series of 17 consecutive patients who presented with upper eyelid edema 6 to 24 months after uneventful HA filler injection in the supraorbital area. RESULTS: The study group included 17 female patients. The average time of presentation was 13.9 months. Thirteen patients (76.4%) were satisfied after hyaluronidase and requested no further treatment (observation only); 4 patients (23.5%) elected to receive HA filler re-treatment, with satisfactory results. All patients were followed-up for at least 6 months after the re-treatment. CONCLUSIONS: The incidence of late-onset upper eyelid edema is likely to increase as the number of patients undergoing HA filler injection to the supraorbital area increases. Our study emphasizes the importance of recognizing this condition and suggests a suitable noninvasive treatment with satisfying results for both the patient and the physician.


Assuntos
Técnicas Cosméticas , Preenchedores Dérmicos , Técnicas Cosméticas/efeitos adversos , Preenchedores Dérmicos/efeitos adversos , Edema/induzido quimicamente , Edema/diagnóstico , Edema/epidemiologia , Pálpebras , Feminino , Humanos , Ácido Hialurônico/efeitos adversos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...